Setup
ESP-ME3
- Turn the dial to Flow Sensor.
- Press – or + to select SENS ON (sensor on) or SENS OFF
- The controller will begin to LEARN FLOW. It will run each station for 3-4 minutes to set the expected station flow.
When set to Sensor ON, automatic irrigation will be suspended per station if detected flow exceeds learned flow by more than 30%. When set to Sensor OFF, all stations will ignore the flow sensor.
When switching from Sensor OFF to Sensor ON, the controller will begin to LEARN FLOW It will run each station for a short period to set the expected station flow.
Turn a flow sensor on or off by station
This feature is useful if you have stations with expected flows outside the operating specification of the FG100.
- Turn the dial to Flow Sensor.
- Press and hold the left and right arrow buttons at the same time.
3. You will now be able to turn off flow sensor by station. Using the left and right arrow buttons to navigate between stations and the + and – buttons to turn the sensor on/ off.